Check MFWD or TLS™ Plus (If Equipped) Axle Housing Oil
Level

RXA0134206-UN-29JUL13
Left-Hand Side
A - Fill/Check Plug
B - Tie Rod
C - TLS™ Plus Accumulator
-
IMPORTANT: If there are any indications of oil leaks, do not
operate tractor until the source has been determined and repairs made.
Park tractor on level ground.
-
Remove fill/check plug (A). Oil level should be just below plug
hole.
-
If oil level is low, add oil until level is correct. Use John
Deere™ Hy-Gard™ oil as specified in Transmission and Hydraulic
Oil in Fuel, Lubricants and Coolant section of this Operator’s
Manual.
-
Apply pipe sealant with TEFLON®, or equivalent, to threads of fill/check plug (A).
-
Install fill/check plug. Tighten to specifications.
| Item | Measurement | Specification |
|
Plugs-to-Axle Housing | Torque | 70 N·m (52 lb.-ft.) |
|
TEFLON is a trademark of Du Pont Co.
|
TO84419,0000065-19-20130821
|
|