iTEC Functions—IVT™/AutoPowr™ Transmission

RXA0134400
RXA0134400-UN-25SEP13

A - Speed Band 1

B - Speed Band 2


iTEC™ allows set speeds for IVT™/AutoPowr™ transmission to be preset. Minimum set speed can be saved is 0.8 km/h (0.5 mph).

Changing set speed or moving lever during execution of sequence will not cause iTEC™ to abort, but set speed changes will not be commanded for remainder of sequence.

If iTEC™ sequence commanded set speed exceeds maximum allowable speed in range selected, set speeds change, but are restricted to highest or lowest allowable set speed in current range. For example, tractor reaches maximum allowable set speed if transmission is in speed range F1 and operator executes 50 km/h (31 mph) command. When set speed is changed by iTEC™, control unit reacts as if operator changed set speed, pushing other set speeds up or down as result.


IVT is a trademark of Deere & Company

AutoPowr is a trademark of Deere & Company

iTEC is a trademark of Deere & Company

TO84419,00000FE-19-20130923