SCV Requirements

Before transferring control to implement, prepare implement as indicated in implement Operator's Manual. Transfer control using AutoTrac™ resume switch as described in implement Operator's Manual.

Following guidelines must be met before transferring control to implement:

  • Operator in seat.
  • SCVs are functional.
  • SCV control levers in neutral position.
  • SCV levers are not locked.

NOTE: Set maximum SCV flow limit which cannot be exceeded by implement.

NOTE: Unless implement is authorized to adjust SCV flow when tractor is stopped, tractor will prevent SCV flow adjustments when at a stop. Implement is however allowed to stop oil flow.

While operating, implement has ability to:

  • Control SCVs during operations.
  • Change SCV flow rate up to set limit.

To disengage control:

  • Actuate specific SCV lever or...
  • Lock SCV lever or...
  • Actuate remote control switch on fender.


AutoTrac is a trademark of Deere & Company

TO84419,0000102-19-20131031