Hydraulic oil overheats
| Low or high oil supply |
Check sight glass and
fill system with correct oil
|
| |
Oil cooler air passages clogged
|
Clean oil cooler
|
| |
Internal hydraulic leak
|
See your John Deere™
dealer
|
| |
Implement hydraulic load not matched to tractor or not
properly routed back into tractor hydraulic system
|
See Remote Hydraulic
Connections
|
| |
Mid-mount valve (If Equipped) flow and detent settings
incorrect
|
Adjust settings. (See
Hydraulics and Selective Control Valves section.)
|
| |
Clogged transmission/hydraulic oil filter
|
Replace filter
|