When Implements Require Large Oil Volumes

CAUTION: Do not add hydraulic oil to reservoir with engine running. Hydraulic reservoir can overflow.

NOTE: Do not overfill the hydraulic reservoir.

Lower the implement to have maximum oil in the reservoir during the checking procedure.

Cycle all implement cylinders after starting tractor.

Check the hydraulic oil reservoir sight gauge level. (See CHECK TRANSMISSION-HYDRAULIC-AXLE OIL LEVEL in the Lubrication and Maintenance Section of the Operator’s Manual).

Lower implement to ground to return maximum amount of oil to reservoir.

Recheck oil level when implement is removed. Add oil if necessary.

Drain any excess oil from hydraulic reservoir using reservoir drain plug.