SCV Requirements

Before transferring control to implement, prepare implement as indicated in implement Operator's Manual. Transfer control using AutoTrac™ resume switch as described in implement Operator's Manual.

Following conditions must be met before transferring control to implement:

  • Operator in seat.
  • SCVs are functional.
  • SCV control levers in neutral position.
  • SCV levers are not locked.

NOTE: Set maximum SCV flow limit which cannot be exceeded by implement.

NOTE: Implement cannot adjust SCV flow when tractor is stopped unless it is authorized to do so. However, implement can stop SCV flow at any time including when tractor is stopped.

While operating, implement has ability to:

  • Control SCVs during operations.
  • Change SCV flow rate up to set limit.

To disengage control, perform any of the following:

  • Actuate specific SCV lever
  • Lock SCV lever
  • Actuate remote control switch on fender.


AutoTrac is a trademark of Deere & Company

TO84419,0000102-19-20160405