Multiple Displays

PC15323-UN-20MAY13
Multiple Displays
Generation 4 CommandCenter may be configured to run with the following John Deere
displays connected at corner post.
- GreenStar 2 1800 Display
- GreenStar™ 3 2630 Display
Some applications, such as AutoTrac, cannot run on both displays at
the same time.
Activations do not transfer between displays. Second display
must have its own activations to run AMS applications.

PC20416-UN-12MAY15
GS3 2630 Display
Installing a GS2 or GS3 Display
-
Ensure that key switch
and CommandCenter™ are off.
-
Attach display harness
to corner post connector and 26-pin display connector to back of display.
-
Turn on key switch.
-
CommandCenter™ display
searches for second display on implement CAN bus for approximately
60 seconds. If CommandCenter™ was previously in Single Display Mode,
it displays a message stating, “Multiple Displays Detected”.
-
Select a configuration
preset:
Single Display
- Do NOT use this option in this scenario. This mode is
only used if second display is not installed.
Multiple Display – Machine Only
- Precision Ag Applications and ISOBUS implements only appear
on second display, not CommandCenter™. Use this option when connected
to an ISOBUS implement with Auxiliary Reconfigurable Control.
Multiple – Implement Viewer
- Precision Ag Applications appear on second display.
- ISOBUS implements appear on CommandCenter™ or second display
depending on the “Next VT display” setting of implement. If ISOBUS implement does not have “Next VT display” function,
implement appears on display that starts up first.
Multiple Display – Precision Ag Applications
- Precision Ag Applications appear on CommandCenter™
- ISOBUS implements appear on second display or CommandCenter™
depending on the "Next VT display" setting of implement. If ISOBUS implement does not have “Next VT display” function,
implement appears on display that starts up first.
Advanced Setup
- Manually set configurations.
Confirm Display Settings
- Run on THIS display: Precision Ag Applications are enabled
on CommandCenter™. Change display settings on other display. Message
displays each time CommandCenter™ is powered up if GreenStar™ applications
are not disabled on other display.
- Run on OTHER display: Precision Ag Applications are disabled
on CommandCenter™. Use GreenStar™ applications on other display.
Change Display Settings
When display settings are changed, corresponding changes must
be made to the other display.
If either of these modes is selected:
- Multiple Display – Precision Ag Applications or Single
Display: Disable GreenStar™ and task controller on other display.
- Single Display: Either disable GreenStar™, task controller,
and implement bus virtual terminal (VT) on other display, or disconnect
other display.
To access multiple display settings on other GreenStar™ displays:
- GreenStar™ 3 2630: Select Menu button > Display button >
Diagnostics softkey > Multiple Displays tab > Change Settings button.
- GreenStar™ 2 1800: Select Menu button > Display button >
Settings softkey > Multiple Displays softkey.
-
Cycle key switch off
and on to save settings.
Removing a GS2 or GS3 Display
-
Ensure that key switch
and CommandCenter™ are off.
-
Detach display harness
from the 26-pin display connector at back of display.
-
Turn on key switch.
-
CommandCenter™ display
searches for second display on Implement CAN bus for approximately
2—3 minutes. If CommandCenter™ was previously in one of the Multiple
Display Modes, it displays a message stating “Second Display Not Found”.
-
Cycle key switch off
and on to save settings.
Removing a Third-Party Display
-
Ensure that key switch
and CommandCenter™ are off.
-
Detach display harness
from third-party display.
-
Turn on key switch.
-
CommandCenter™ display
searches for second display on Implement CAN bus for approximately
2—3 minutes. If CommandCenter™ was previously in one of the Multiple
Display Modes, it displays a message stating, “Second Display Not
Found”. If the “Second Display Not Found” message does not appear
after 3 minutes, skip to step 5.
-
Ensure CommandCenter™
is in Single Display Mode and third-party display is unplugged.
-
Cycle key switch off
and on to save settings.
Operating AutoTrac™ on CommandCenter™
Generation 4 OS software updates 2015-1 (8.12.2500-17)
and 2015-2 (10.0.49-59 or 10.0.49-65) disable Precision Ag Applications
when a secondary GreenStar™ display is detected. Disconnect GreenStar™
display inside cab to operate Precision Ag functions on Generation
4 CommandCenter™ with these software versions.
After installing a GS3 2630 Display, AutoTrac™ defaults to that
display. Follow these instructions to run AutoTrac™ on CommandCenter™.
After procedure, GS3 2630 Display will not run any GreenStar™
applications, including Section Control.
-
Ensure CommandCenter™
is in Single Display Mode and GS3 2630 Display is unplugged. Turn
key switch off.
-
Plug in GS3 2630 Display
and turn on key switch.
-
When CommandCenter™ boots
up, select Multiple – Compatibility Mode. Reboot display.
-
On GS3 2630 Display,
select Menu button > Display button > Diagnostics softkey > Multiple
Displays tab. Turn off GreenStar™ application. Depending on configuration,
display may reboot.
-
On CommandCenter™, select
Display and Sound application > Multiple Displays tab. Turn on Precision
Ag Applications. Reboot display.
|
CommandCenter is a trademark of Deere & Company
GreenStar is a trademark of Deere & Company
AutoTrac is a trademark of Deere &
Company
|
DX,PC,DISP,MULTI-19-20170407
|
|