Total Rear SCV Flow
-
Check flow setting for
each function independently (see implement operator's manual
Specifications section to determine correct motor flow settings).
Following can cause pump to operate at high pressure:
- Down pressure systems (drills, air seeders, disks) can
be considered to be zero flow demand after completion of raise or
lower cycle (see Implement Connection examples in Hydraulic Connections
section).
- Auxiliary flow control valves (vacuum flow control) -
Open implement flow control valve and adjust tractor flow rate to
desired setting (see Implement Connection examples in Hydraulic Connections
section).
- Cylinder functions where line or orifice restrictions
control flow - Adjust tractor flow control to point where function
speed begins to decrease.
- Auxiliary control valves (implement stack valves, row
guidance) adjust tractor flow control to lowest setting resulting
in correct operation.
-
Determine total flow
demand by adding flow requirements for each SCV using settings determined
in Step 1. Include hitch and power beyond flow requirements, if applicable
(refer to chart for correct settings).
-
Determine if flow demand
exceeds available pump flow (refer to chart for available pump flow):
- Flow demand is less than available pump flow but has performance
concern (see your John Deere™ dealer).
- Flow demand exceeds pump flow:
- Increase engine RPM if possible.
- Decrease flow setting on noncritical functions.
- Convert implement open center valves to closed center
operation, if equipped.
Flow measurements made without steering or hitch being
used.
|
SCV FLOW (Approximate)
|
|
Engine rpm
|
Pump Flow (90 cc Pump) L/min (gpm)
|
Hi Flow Pump Flow (90 cc Pump L/min (gpm) + 85 cc Pump) Optional
|
|
1000
|
106.4 (28)
|
207.3 (55)
|
|
1500
|
159.5 (42)
|
310.9 (82)
|
|
2000
|
212.7 (56)
|
414.6 (110)
|
|
2100
|
220 (58)
|
435 (115)
|
|
SCV FLOW OUTPUT (Approximate)1
|
|
SCV Flow Settings
|
L/min (gpm)
|
|
0.12
|
—
|
|
1.0
|
1.9 (0.5)3
|
|
2.0
|
6.1 (1.6)
|
|
3.0
|
13.6 (3.6)
|
|
4.0
|
20.4 (5.4)
|
|
5.0
|
28.0 (7.4)
|
|
6.0
|
40.9 (10.8)
|
|
7.0
|
62.1 (16.4)
|
|
8.0
|
81.4 (21.5)
|
|
9.0
|
107.1 (28.3)
|
|
10.0
|
132 (35)
|
|
SCV HIGH FLOW OUTPUT (Approximate)
This 3/4” coupler is only available for SCV I as a field
installed kit or for a Scraper Tractor Configuration.
|
|
SCV Flow Settings
|
Flow
|
|
L/min
|
gpm
|
|
0.1 4
|
—
|
—
|
|
1.0
|
4.3
|
1.1
|
|
2.0
|
11.3
|
3.0
|
|
3.0
|
19.4
|
5.1
|
|
4.0
|
27.6
|
7.3
|
|
5.0
|
35.2
|
9.3
|
|
6.0
|
49.9
|
12.4
|
|
7.0
|
72.0
|
19.0
|
|
8.0
|
95.3
|
25.2
|
|
9.0
|
118.6
|
31.4
|
|
10.0
|
159
|
42
|
|
Hitch Flow
|
|
Hitch Cylinder
|
Flow
|
|
Diameter (mm)
|
L/min
|
gpm
|
|
90/100
|
71
|
18.7
|
|
120/120
|
88
|
23.2
|
|
1 At 2000 rpm and 454 kg (1000
lbs) of load at point of use.
2 0.1 = Minimum
Flow Setting
3 Observed under no load.
4 0.1 = Minimum
Flow Setting
|
RD47322,00002C3-19-20170823
|
|