Engine Oil and Filter Service Intervals — Tier 2 and Stage
II — OEM Applications
Recommended oil and filter service intervals are based on a
combination of oil pan capacity, type of engine oil and filter used,
and sulfur content of the diesel fuel. Actual service intervals also
depend on operation and maintenance practices.
Use oil analysis to evaluate the condition of the oil and to
aid in selection of the proper oil and filter service interval. Contact
your John Deere dealer or other qualified service provider for more
information on engine oil analysis.
Change the oil and oil filter at least once every 12 months
even if the hours of operation are fewer than the otherwise recommended
service interval.
Diesel fuel sulfur content affects
engine oil and filter service intervals.
-
Use of diesel fuel with sulfur content less than 2000 mg/kg
(2000 ppm) is RECOMMENDED.
-
Use of diesel fuel with sulfur content 2000—5000 mg/kg
(2000—5000 ppm) REDUCES the oil and filter change interval.
-
BEFORE using diesel fuel with sulfur content greater than 5000
mg/kg (5000 ppm), contact your John Deere dealer or qualified service
provider.
IMPORTANT: To avoid engine damage:
-
Reduce oil and filter service intervals by 50% when using biodiesel
blends greater than B20. Oil analysis may allow longer service intervals.
-
Use only approved oil types.
Approved Oil Types:
-
“Plus-50 Oils” include John Deere Plus-50 II and John Deere
Plus-50™.
-
“Other Oils” include John Deere Torq-Gard Supreme,
API CK-4, API CJ-4, API CI-4 PLUS, API CI-4, API CH-4, ACEA E9, ACEA
E7, ACEA E6, ACEA E5, and ACEA E4.
NOTE: The 500-hour extended oil and filter change interval is
only allowed if all of the following conditions are met:
-
Engine equipped with an extended drain interval oil pan.
-
Use of diesel fuel with sulfur content less than 2000 mg/kg
(2000 ppm).
-
Use of John Deere Plus-50™ II or John Deere Plus-50™
oil.
-
Use of an approved John Deere oil filter.
|
Engine Oil and Filter Service Intervals
|
| |
Standard Drain Oil Pan
|
Extended Drain Oil Pan
|
|
Fuel Sulfur
|
Less than 2000 mg/kg (2000 ppm)
|
|
Plus-50 Oils
|
375 hours
|
500 hours
|
|
Other Oils
|
250 hours
|
250 hours
|
|
Fuel Sulfur
|
2000—5000 mg/kg (2000—5000 ppm)
|
|
Plus-50 Oils
|
275 hours
|
400 hours
|
|
Other Oils
|
150 hours
|
150 hours
|
|
Fuel Sulfur
|
5000—10000 mg/kg (5000—10000 ppm)
|
|
Plus-50 Oils
|
187 hours
|
250 hours
|
|
Other Oils
|
125 hours
|
125 hours
|
|
Oil analysis may extend the service interval of “Other
Oils”, to a maximum not to exceed the interval of Plus-50 Oils.
Oil analysis means taking a series of oil samples at 50-hour increments
beyond the normal service interval until either the data indicates
the end of useful oil life or the maximum service interval of John
Deere Plus-50 oils is reached.
|
|
Plus-50 is a trademark
of Deere & Company
Torq-Gard is
a trademark of Deere & Company
|
DX,ENOIL12,T2,OEM-19-20180113
|
|