PV480 Diagnostic Gauge — Essential Menus

    Automatic Exhaust Filter Cleaning

    To enable auto exhaust filter cleaning mode:

  1. Press Menu key on diagnostic gauge.
  2. Press Arrow keys to scroll up or down to EXHAUST FILTER.
  3. Press Select key.
  4. Press Arrow keys to scroll up or down to AUTO EXH FLT CLEAN.
  5. Press Select key to enable auto exhaust filter cleaning.

    Manual/Parked Exhaust Filter Cleaning

    To request a manual/parked exhaust filter cleaning:

  1. Reduce engine speed to slow idle.
  2. Press Menu key.
  3. Press Arrow keys to scroll up or down to EXHAUST FILTER.
  4. Press Select key.
  5. Press Arrow keys to scroll up or down to REQUEST EXH FLT CLEAN.
  6. Press Select key to request a manual/parked exhaust filter cleaning.
  7. Follow directions on display and ensure all conditions are met.
  8. Press Select key to CONFIRM all conditions are met.

    Disable Exhaust Filter Cleaning

    To disable the auto exhaust filter cleaning mode:

  1. Press Menu key on diagnostic gauge.
  2. Press Arrow keys to scroll up or down to EXHAUST FILTER.
  3. Press Select key.
  4. Press Arrow keys to scroll up or down to DISABLE EXH FLT CLEAN.
  5. Press Select key to disable exhaust filter cleaning.

    Fault Codes — Active

    To view active fault code information:

  1. Press Menu key on diagnostic gauge.
  2. Press Arrow keys to scroll up or down to FAULTS.
  3. Press Select key.
  4. Press Arrow keys to scroll up or down to ACTIVE FAULTS.
  5. Press Select key.
  6. Press Arrow keys to scroll through available faults.

    Fault Codes — Stored

    To view stored fault code information:

  1. Press Menu key on diagnostic gauge.
  2. Press Arrow keys to scroll up or down to FAULTS.
  3. Press Select key.
  4. Press Arrow keys to scroll up or down to STORED FAULTS.
  5. Press Select key.
  6. Press Arrow keys to scroll up or down to VIEW.
  7. Press Select key.
  8. Press Arrow keys to scroll through available faults.

BL90236,0000024-19-20210819