Precautions For Welding On Vessels Equipped With Electronic
Engine Control Unit (ECU)

TS953-UN-15MAY90
Welding Precautions
IMPORTANT: ALWAYS disconnect Electronic Control Unit (ECU) connectors
and engine control system-to-vessel ground before welding. High currents
or electro-static discharge in electronic components from welding
may cause permanent damage.
-
Remove the ground connection for the engine control system-to-vessel
frame.
-
Disconnect the connectors from the ECU.
-
Connect the welder ground close to the welding point and be
sure ECU or other electronic components are not in the ground path.
|
|
DPSG,OUOD007,2898-19-20131113
|
|