Intermittent Fault Diagnostics
Intermittent faults are problems that periodically “go
away”. A problem such as a terminal that intermittently doesn't
make contact can cause an intermittent fault. Other intermittent faults
may be set only under certain operating conditions such as heavy load,
extended idle etc. When diagnosing intermittent faults, take special
note of the condition of wiring and connectors since a high percentage
of intermittent problems originate here. Check for loose, dirty or
disconnected connectors. Inspect the wiring routing looking for possible
shorts caused by contact with external parts (for example, rubbing
against sharp sheet metal edges). Inspect the connector vicinity looking
for wires that have pulled out of connector terminals, damaged connectors,
poorly positioned terminals, and corroded or damaged terminals. Look
for broken wires, damaged splices, and wire-to-wire shorts. Use good
judgement if component replacement is thought to be required.
NOTE: The Engine Control Unit (ECU) is the component LEAST likely
to fail.
Suggestions for diagnosing intermittent faults:
If the problem is intermittent, try to reproduce the operating
conditions that were present when the Diagnostic Trouble Code (DTC)
set.
If a faulty connection or wire is suspected to be the cause
of the intermittent problem: clear DTCs, then check the connection
or wire by wiggling it while watching the diagnostic gauge to see
if the fault resets.
Possible Causes of Intermittent Faults:
-
Faulty connection between sensor or actuator and harness.
-
Faulty contact between terminals in connector.
-
Faulty terminal/wire connection.
Electromagnetic interference (EMI) from an improperly installed
2-way radio, etc. can cause faulty signals to be sent to the ECU.
NOTE: Refer to wiring diagram foldouts earlier in this section
as a guide to connections and wires.
|
|
OURGP11,0000206-19-20031007
|
|