1 Replace primary air cleaner
element when restriction indicator shows a vacuum of 625 mm (25 in.)
H2O. If not equipped with indicator, replace air cleaner elements
at 500 hours or 12 months, whichever occurs first.
2 During engine break-in, change the oil and
filter for the first time after 100 hours of operation (maximum).
3 Service
intervals depend on sulfur content of the fuel, oil pan capacity,
and the oil and filter used. (See ENGINE OIL AND FILTER SERVICE INTERVALS
(JET FUEL CAPABLE ENGINES ONLY) earlier in this manual.)
4 Replace
crankshaft damper every 4500 hours or 60 months, whichever occurs
first.
5 If John Deere COOL-GARD is used, the flushing
interval may be extended to 3000 hours or 36 months. If John Deere
COOL-GARD is used and the coolant is tested annually AND additives
are replenished as needed by adding a supplemental coolant additive,
the flushing interval may be extended to 5000 hours or 60 months,
whichever occurs first.
|