Set Control Lever Detents
NOTE:
Read operators manual symbol (A) is for reference only and is not a selectable setting.
SCV Section/Knob Position/Operation |
Control Lever Detent |
SCV III-Centered (C) for loader operation |
(C)-No Detent-Lever returns to neutral when released |
SCV II-Turned counterclockwise (B) for motor operation |
(B)-Continuous Detent-Holds lever in operating position until manually returned to neutral |
SCV I-Turned clockwise (D) for cylinder operation |
(D)-Automatic Detent-Lever automatically returns to neutral when cylinder reaches end of stroke |
With lever in neutral, remote cylinder is hydraulically locked in position.
IMPORTANT:
To avoid overheating hydraulic oil and damage to tractor, use SCV I when long duration "continuous" (motor) operation is required. Valve I of the Deluxe SCV has a flow control valve which, when properly adjusted, provides flow to operate an implement at required speed while maintaining oil temperature within normal operating range.
Valve II and III can be set to "continuous" (motor) detent, but this position should only be used for intermittent applications (not exceeding 10 min/hr maximum) or hydraulic oil will overheat and damage tractor.
|
Viewed From Operator's Station
A-Read Operator's Manual
B-Continuous Detent (Motor)
C-No Detent (Loader)
D-Automatic Detent (Cylinder)
|