QRL switches are not working
Check and connect wiring harness properly at switch end
QRL ECU have a problem
Check QRL ECU for its proper functioning and contact John Deere dealer
Check QRL ECU wiring connections
3 point linkages not responding to QRL switch functions
Fill transmission/hydraulic oil to its desired quantity
Transmission/hydraulic oil not circulating in the rockshaft system
Start engine and keep it in idle condition for few seconds so that transmission/hydraulic oil starts circulating I the rockshaft system
QRL motor not running
Check and connect wiring harness properly at motor end
Motor damaged
check and replace motor if damaged
QRL Indicator not giving any indication when QRL problem occurs
Check instrument cluster and QRL indicator wiring connections and connect them properly
QRL ECU not sending signals to QRL indicator
AH98466,000123B-19-20110207