Service Battery
PY15140-UN-03APR12
A - Negative (-) Battery Cable
B - Positive (+) Battery Cable
-
Keep battery clean by wiping with a damp cloth. Keep all connections
(A and B) clean and tight. To remove any corrosion, wash terminals
with a solution of four parts water to one part baking soda.
-
CAUTION: To avoid sparks, connect negative (ground) (-) cable
last and disconnect it first.
Keep battery fully charged, especially during cold weather.
If a battery charger is connected, attach a positive cable to the
positive battery terminal (B). Connect the negative battery charger
lead to a good ground on tractor frame.
-
CAUTION:
TS203-UN-23AUG88
Sulfuric acid in battery electrolyte is poisonous. It is
strong enough to burn skin, eat holes in clothing, and cause blindness
if splashed into eyes.
Avoid the hazard by:
-
Filling batteries in a well-ventilated area.
-
Wearing eye protection and rubber gloves.
-
Avoiding breathing fumes when electrolyte is added.
-
Avoiding spilling or dripping electrolyte.
-
Use proper jump start procedure.
If you spill acid on yourself:
-
Flush your skin with water.
-
Apply baking soda or lime to help neutralize the acid.
-
Flush your eyes with water for 15—30 minutes. Get medical
attention immediately.
If acid is swallowed:
-
Do not induce vomiting.
-
Drink large amounts of water or milk, but do not exceed 2 L
(2 quarts).
-
Get medical attention immediately.
IMPORTANT: DO NOT add water in freezing weather unless tractor
will be run at least 30 minutes to assure thorough mixing.
PY4503-UN-14JAN05
A - Battery Cells
Check level of electrolyte in each cell (A) at least every
250 hours. If low, fill to bottom of filler necks with CLEAN, SOFT
water. DO NOT OVERFILL.
-
Coat terminals with a small amount of grease.
|