Remove Primary Air Cleaner Element

PY19065
PY19065-UN-24SEP13

PY1113
PY1113-UN-29JUL01

A - Rubber Strap

B - Clip (3 used)

C - Primary Element


  1. Disconnect rubber strap (A) at the front of the canister.

  2. Lift clip (B) and pull canister cover.

  3. Clean out any dirt in canister taking care not to damage the secondary filter element.

  4. Removal of the secondary element is similar to removal of the primary element.

IMPORTANT: Remove secondary element (inner element) ONLY if it is to be replaced. DO NOT attempt to clean secondary element. If secondary element is replaced, install new element immediately to prevent dust from entering air intake system. When replacing the air cleaner canister, make sure that the dust cup/ejector hose is facing downward.

SP21231,0001427-19-20131010