A dual element air cleaner is standard. A dirty primary element
is indicated when air restriction indicator on instrument panel illuminates.
A dirty element can result in loss of power or excessive smoke.
Clean primary element when indicator on instrument panel illuminates
or every 250 hours.
Both elements should be replaced at the same time annually,
regardless of condition.
-
Raise hood by unlocking the key.
-
Release Latch (B) and remove Cover (C) from sideways.
-

PY21406-UN-22AUG14
Primary Element

PY21407-UN-22AUG14
Secondary Element
A - Primary Filter Element
B - Secondary Filter Element
Rotate Primary filter element anticlock wise to remove. Do
not use excessive force. If filter does not pull out with ease, check
for unlock position to remove safely.
-
Clean primary element by tapping gently on palm of your hand.
DO NOT tap element against a hard surface. Clean element with blowing
compressed air (Max pressure of 1.3 Bar /20 PSI). Hold nozzle next
to inner surface, and move up and down pleats.
IMPORTANT: DO NOT direct air against outside of element, as
it might force dirt through to inside.
-
Clean out any dirt in canister taking care not to damage the
secondary filter element (B).
-
Secondary filter element (B) should only be removed when being
replaced. If it looks dirty or damaged do not attempt to clean, replace
it. Removal of the secondary element (B) is similar to removal of
the primary element.
-
Install secondary filter element (B) carefully and lock the
filter by rotating the ¼ turn in clockwise direction.
IMPORTANT: If primary filter is not damaged and indicator on
instrument panel remains illuminated, replace both filters.
-
Installation of the primary filter element (A) is similar to
installation of the secondary filter element (B).
-
Close cover and raise latch.
-
Lower hood and lock by key.