Check MFWD Axle Housing Oil Level

LV14247-UN-10MAY11
A - Plug
|
Service Interval—50 Hours
|
-
Park tractor on level surface.
-
Remove plug (A). Oil level should be approximately 12 mm (1/2
in.) below edge of plug hole.
-
If low, add oil through same hole. John Deere Hy-Gard oil is recommended.
(See Fuels, Lubricants and Coolant section.)
-
NOTE: Approximate MFWD axle housing oil capacity is 4.5 L (1.19
gal).
-
Apply pipe sealant with TEFLON®, or equivalent, to threads of plug.
-
Install plug and tighten to specifications.
| Item | Measurement | Specification |
|
Plug-to-Axle Housing | Torque | 70 N·m (52 lb-ft) |
|
Hy-Gard is a trademark
of Deere & Company
TEFLON is a trademark of Du Pont Co.
|
SD74272,000026B-19-20120927
|
|