Connect Single-Acting Cylinder

PY39872-UN-20JUL17
Right Side Controls, IOOS

PY39874-UN-20MAR17
Right Side Controls, CAB

PY39876-UN-20MAR17
SCV Couplers, OOS

PY39875-UN-20MAR17
SCV Couplers, CAB
A - SCV I Lever
B - SCV II Lever (If Equipped)
C - SCV I Coupler (Cylinder in Extract Position)
D - SCV I Coupler (Cylinder in Retract Position)
E - SCV II Coupler (Cylinder in Extract Position)
F - SCV II Coupler (Cylinder in Retract Position)
In order for lever (A and B) to work properly, a single-acting
cylinder should be connected only to extend hose SCV outlet.
IMPORTANT: Volume of oil required to extend cylinder must not
lower transmission-hydraulic oil level. Check oil level with cylinder
fully extended. (See Transmission-Hydraulic System )
Push SCV control lever full forward to use “float”
position to lower single-acting cylinder.
“Float” position allows a cylinder to extend and
retract freely and uses no engine power.
SCV I - Colored in Green.
SCV II - Colored in Blue.
NOTE: SCV II is optional and operation of SCV II is same as
SCV I.
|
|
HY01057,0000122-19-20170713
|
|