Use Power Beyond Attachment (If Equipped)

PY41777-UN-18JUL17

PY41776-UN-18JUL17

PY41780-UN-18JUL17
A - Plug
B - Hydraulic hose (PBP port power beyond to mid mount
SCV)
C - Hydraulic hose (Outlet port power beyond to mid
mount SCV)
D - Hydraulic hose (Inlet port of power beyond to mid
mount SCV)
Power beyond is designed for operations of orbital motors or
any application where continuous high volume hydraulic oil flow is
needed.
To use power beyond remove three plugs (A), connect hose (B)
from power beyond to mid mount SCV, power beyond outlet hose (C) to
mid mount SCV, and connect inlet hose (D) from power beyond to mid
mount SCV.
When not in use, plug power beyond and mid mount valve.
NOTE: Images shown for OOS tractors, for CAB tractors hydraulic
hose connection same as OOS tractor.
|
|
NM61126,00004E1-19-20170718
|
|