Operate Rear SCV Control Levers

causym CAUTION: Overheated hydraulic oil can cause personal injury and component malfunctions. To prevent hydraulic oil from overheating, DO NOT hold Selective Control Valve (SCV) control lever in operating position for an extended period of time.

Rear selective control valve (SCV) control levers have four positions:

  • Extend
  • Retract
  • Neutral
  • Float

Float is the only position with mechanical detent. Extend and retract automatically spring back to neutral when lever is released. Float has to be manually returned to neutral.

To EXTEND cylinder, pull lever REARWARD.

To RETRACT cylinder, push lever FORWARD.

To bring cylinder in NEUTRAL position, release lever to CENTER position.

To bring cylinder in FLOAT position, push lever further FORWARD past retract.

To prevent SCV levers from moving unintentionally, use SCV lockout levers (D).

PULV004953

SCV levers


A-SCV I control lever
B-SCV II control lever-If equipped
C-SCV III control lever-If equipped
D-SCV lockout lever

HP51992,0000097 -19-02SEP09-1/1