Clean Engine Crankcase Vent Tube

P13401
P13401-UN-17DEC04

A - Crankcase vent tube


Service Interval — Every 1000 hours

CAUTION: Reduce compressed air to less than 210 kPa (2bar) (30 psi) when using for cleaning purposes. Clear area bystanders, guard against flying chips, and wear personal protection equipment including eye protection.

Remove crankcase vent tube (A) from engine. Wash in solvent or blow clean with compressed air. Reassemble vent tube breather cap to engine. Be sure vent tube is not kinked or pinched.

PX07220,0000038-19-20041018