Adjusting the Oil Flow

Operating at excessive speed may cause injury and machine damage.

Setting the oil flow rate only works on Selective Control Valve I.

Oil flow rate determines the working speed of the implement. Adjust oil flow rate by turning the metering valve knob (A):

BM018501
BM018501-UN-25NOV16

A - Flow Rate Regulating Valve

  • Counterclockwise: Increases flow rate
  • Clockwise: Reduces flow rate

On some implements in detent function the SCV lever may return to neutral too early, making it necessary to reduce oil flow rate.

GE12815,0000096-19-20161126