Verification Thermostat Opening Temperature

CQ294097
CQ294097-UN-06AUG12


  1. Remove thermostat.

  2. Visually inspect thermostat for corrosion or damage.

  3. DO NOT allow thermostat or thermometer to rest against the side or bottom of container when heating water. Either may rupture if overheated.

    Suspend thermostat and thermometer in a container of water.

  4. Stir the water as it heats. Observe opening action of thermostat and compare temperatures with specification given in chart below.

    Due to varying tolerances of different suppliers, initial opening and full open temperatures may vary slightly from specified temperatures.

    THERMOSTAT TEST SPECIFICATION

    Rating

    Initial Opening (Range)

    Full Open (Nominal)

    82°C (180°F)

    80-84°C (175-182°F)

    94°C (202°F)

  5. Remove thermostat from container and observe closing action as thermostat cools. Thermostat should close completely in ambient air. Closing action should be smooth and slow.

  6. Replace thermostat if defective.