Daily Service Before Starting Engine
Park tractor on level ground before executing checks.
-
CQ294690-UN-25JUL13
5075E Tractor
CQ294691-UN-25JUL13
5078E, 5085E and 5090E Tractors
CQ294692-UN-25JUL13
Check engine oil level. Clean dipstick (A) and reinsert fully.
Withdraw it again and check oil level.
The window for safe operation of engine is when the oil level
is between MAX and MIN dipstick marks.
Do not operate engine if oil level is below MIN dipstick mark.
In this case, add oil recommended in Section (Fuel, Lubricants and
Coolant) through filler neck (B).
-
Check coolant level at radiator expansion reservoir. If the
engine is cold and coolant level is below LOW mark, add coolant to
expansion reservoir until level reaches LOW mark.
With engine cold, coolant level should be at LOW mark.
At operating temperature, coolant level of tractor should be at FULL
mark.
-
If you are operating the tractor in extremely wet or excessively
muddy conditions, lubricate grease points indicated in interval (Service—Daily
or Every 10 Hours).
-
Check transmission/hydraulic system oil level. Remove dipstick
(C), clean and reinsert fully.
Oil level should be between MIN and MAX marks on dipstick. If
oil level is low, add oil recommended in Section (Fuel, Lubricants
and Coolant) through filler neck.
Use Multipurpose Grease
See Section (Fuel, Lubricants and Coolant) for grease specifications.
|
JG50163,0000252-19-20131205
|
|