Important Instructions Regarding Alternator
The alternator is equipped with a voltage regulator.
CQ294955-UN-04DEC13
Connections
-
Red battery cable (A).
-
Black cable (B) to hour meter and battery charge warning light
(instrument panel).
If it is necessary for the engine to operate without a battery
(starting up the engine by means of an auxiliary battery), do not
operate the engine above 1000 rpm. Engage some electrical systems
(lights) while the engine is running.
When the battery is removed and the engine is started up by
means of an auxiliary battery, in which case the loose current carrying
cable must be insulated to prevent damage to the alternator and regulator.
Never short circuit or bypass the ground of the alternator
or regulator with the engine running.
Connect battery charger with correct polarity. If connections
are inverted (+) and (-), the rectifying diodes will be immediately
destroyed.
Before carrying out any electrical welding jobs on
the tractor, disconnect both alternator cables.
Connect ground terminal of welding apparatus directly to the
part being welded.
Before carrying out repairs on electrical system, disconnect
battery ground cable (-). This will prevent risk of a short circuit.
|
OU90500,00001AF-19-20131204
|
|