Changing Engine Oil and Replacing Oil Filter
Change engine oil and oil filter after 100 working
hours. After that, change every 250 hours or after one year, whichever
occurs first. The interval for changing the oil can be extended from
250 to 375 hours if JD Plus-50, JD Plus-50 II or ACEA classification oil E4, E5, E6 and E7 is used.
-
Start engine and keep it running for some minutes.
-
Park tractor on level terrain.
-
Shut engine OFF.
-
Place a suitable container under drain plug (A).
-
Remove drain plug (A) from engine crankcase.
CQ294684-UN-25JUL13
5075E Tractor
CQ294685-UN-25JUL13
5078E, 5085E and 5090E Tractors
CQ294682-UN-25JUL13
5075E Tractor
CQ294683-UN-25JUL13
5078E, 5085E and 5090E Tractors
A - Drain Plug
B - Engine Oil Filter
C - Filler Neck
D - Oil Dipstick
-
Drain oil out.
-
Reinstall the drain plug (A).
-
Replace engine oil filter (B).
Apply a fine film of clean oil to the oil filter seal
before installing the filter. Manually tighten engine oil filter.
-
Add specified oil through filler neck (C).
Check the engine oil capacity in Specifications Section.
Use oil as specified in Fuels, Lubricants, and Coolant
Section.
-
Start and run engine a few minutes.
-
Shut engine OFF.
-
Check tractor for oil leaks.
-
Wait 45 minutes.
-
Check engine oil level using oil level dipstick (D). Add oil
if necessary.
|
OU90500,00001B6-19-20170814
|
|