Starter Wiring Connections

CAUTION: To avoid shocks and burns, disconnect negative (-) cable before servicing any part of the electrical system.

Make all connections before reconnecting ground cable.

P14575
P14575-UN-05NOV07

Right Hand Side

A - Cable From Fusible Link

B - Positive Battery Cable

C - Large Terminal

D - Small Wire

E - Small Terminal

Cable (A) from fusible link and positive battery cable (B) are connected to large terminal (C).

To remove small wire (D) open tab and loosen screw on small terminal (E). To reinstall small wire reinsert wire, tighten screw and close tab.

NS43404,000054C-19-20071105