Check Engine and Exhaust Compartments for Debris

IMPORTANT: Directing pressurized water at electronic/electrical components, connectors, bearings and hydraulic seals, fuel injection pump or other sensitive components can cause product malfunctions. Reduce pressure and spray at a 45 to 90 degree angle.

Directing pressurized air at electronic/electrical components or connectors can cause buildup of static electricity and product malfunctions.

Never steam clean or pour cold water on an injection pump that is operating or hot. Pump could seize.

  1. Shut off engine and allow time to cool.

  2. Open and raise engine hood.

  3. Remove any crop or debris within engine and exhaust compartments, especially around turbocharger, exhaust manifold, and exhaust aftertreatment system.

  4. Reinstall all shields. Close and securely latch hood.

DP51502,00025F0-19-20161028