SCV and Loader Settings


SCV I — IV

RXA0152942
RXA0152942-UN-01AUG16

SCV I Icon

RXA0152943
RXA0152943-UN-21JUL16

SCV II Icon

RXA0152944
RXA0152944-UN-21JUL16

SCV III Icon

RXA0154074
RXA0154074-UN-23SEP16

SCV IV Icon

Rear SCV I — III flows are adjustable for the application. A higher flow value increases the hydraulic oil flow to the function.

The time which the SCV is commanded to operate at maximum flow is also adjustable. Flow is set for a time interval or continuous.

Rear SCV IV EH valve is a non adjustable ON-OFF valve. This valve is only available on Closed Center Hydraulics. With Open Center Hydraulics, SCV IV is mechanical and the flow is adjustable.


SCV XI — XIII

RXA0152945
RXA0152945-UN-21JUL16

SCV XI Icon

RXA0152946
RXA0152946-UN-21JUL16

SCV XII Icon

RXA0152947
RXA0152947-UN-21JUL16

SCV XIII Icon

Mid SCV XI — XIII flows are adjustable for the application. A higher flow value increases the hydraulic oil flow to the function.

The time which the SCV is commanded to operate at maximum flow is also adjustable. Flow is set for a time interval or continuous.


Loader Mode

RXA0152948
RXA0152948-UN-21JUL16

Loader Mode Selection

When loader mode is turned on, SCV XI — XIII timed detents are turned off to provide instant reaction to controls. The bucket rattle feature is enabled to allow the operator to shake material out of the bucket.