Automatic (AUTO) Exhaust Filter Cleaning

LV23058-UN-12SEP14

PY42057-UN-15MAY17
A - Exhaust Filter Cleaning Mode Switch
B - Engine Emissions Temperature Indicator
IMPORTANT: Do not disable automatic exhaust filter cleaning
unless it is necessary. If disabled mode is used frequently, system,
eventually, reduces engine performance requiring a stationary parked
exhaust filter cleaning.
CAUTION: To prevent fires, be sure to, routinely, clear combustible
materials (crop debris, animal nests, and others) away from the area
of the engine and exhaust filter. Exhaust filter cleaning uses extremely
high temperature.
Automatic exhaust filter cleaning is started when sulfur or
urea deposits in the exhaust filter reach a certain level. Automatic
exhaust filter cleaning is initiated and performed without any intervention
on the part of the operator.
Exhaust filter cleaning mode switch (A) is a momentary contact
switch. Default position is Automatic (AUTO) Exhaust Filter Cleaning
mode.
If the system determines that sulfur or urea deposit buildup
in the exhaust filter requires cleaning and engine speed is above
1200 rpm, an automatic cleaning is initiated and performed. Engine
emissions temperature indicator (B) remains illuminated during the
exhaust filter cleaning.
|
|
GS25068,0005A94-19-20181009
|
|