Machine Storage

IMPORTANT: Anytime machine is not used for several months, use this procedure to minimize corrosion and deterioration. Use an engine storage kit and an extra 0.95 L (1 pt) of the corrosion inhibitor. See your John Deere dealer.

Long-term storage of Diesel Exhaust Fluid in the DEF tank (over 12 months) is not recommended. If long-term storage is necessary, test DEF before operating engine. (See Fuel, Lubricants, and Coolants section.)

NOTE: Whenever possible, store machine in a building or under a roof to avoid damage resulting from prolonged exposure to the elements.

Perform the following steps to place the machine into storage:

  1. Service air cleaner. (See Air, Fuel, Coolant, and Exhaust Maintenance section.)

  2. Change engine oil and filter. (See Engine Maintenance section.)

  3. If coolant has not been changed within the last 2 years, flush cooling system. See your John Deere dealer. Add 50% antifreeze/water mixture. Test coolant for adequate cold-weather protection.

  4. Add 0.5 L (16 oz) of the corrosion inhibitor to engine at the oil fill cap.

  5. Add 0.25 L (9 oz) of the corrosion inhibitor to the transmission/hydraulic reservoir at the oil fill cap.

  6. Drain fuel and add back 4 L (1 gal) of fuel. Then add 0.5 L (16 oz) of the corrosion inhibitor to fuel tank.

  7. Depress clutch and start engine. Run engine until it reaches operating temperature. Also raise and lower rear hitches several times. When done, fully lower rear hitch to retract cylinders.

  8. Shut off engine.

  9. Remove air intake hose at the manifold. Pour 0.1 L (3 oz) inhibitor into manifold and replace hose.

  10. Disconnect crankshaft position sensor wiring connector. (Preventing engine from starting while engaging the starter.)

  11. Pull hand throttle back to low idle position. Crank engine only a few revolutions.

  12. Release tension on auxiliary drive belts. Remove belt from the air conditioner pulley and fan pulley.

  13. Remove and clean battery. Store in a cool, dry place. Keep battery charged. Disconnect battery ground cable for short-term storage periods (30 to 90 days). (See Electrical and Lighting Maintenance section.)

  14. Coat exposed metal surfaces, such as steering cylinder rods, if extended, with grease or a corrosion inhibitor.

  15. Seal air inlets, exhaust, crankcase fill cap, fuel tank cap, radiator overflow hose, and transmission and hydraulic system fill cap using plastic bags and tape.

  16. Protect tires from heat and sunlight:

    • Raise tires off the ground (move machine once a month if tires are not raised off the ground).
    • Cover wheels with waterproof tarpaulin.
    • Avoid storing at temperatures greater than 29°C (85°F).
    • Avoid direct sunlight.

  17. Thoroughly clean machine. Touch up any painted surfaces that are scratched or chipped.

  18. Wax machine.

  19. If machine is stored outside, follow additional precaution: Cover instrument panel, control levers, and seat with sheets of material or cardboard, or cover entire machine with waterproof material to protect against the sunlight.