Service Air Cleaner Elements

MAINTENANCE INTERVAL

 

Every 1200 Hours Maintenance air cleaner more often in extremely dusty condition

PY42071
PY42071-UN-17MAY17

CPA0004211
CPA0004211-UN-09AUG17

RXA0156171
RXA0156171-UN-14DEC16

A - Air Filter Restriction Indicator

B - Latch

C - Cover

D - Primary Air Cleaner Element

E - Guide Ring

F - Secondary Air Cleaner Element


IMPORTANT: Dirty air cleaner element is indicated when air filter restriction indicator (A) appears on the information display.

  1. Open hood.

  2. Remove latch (B) and cover (C).

  3. Remove air cleaner element (D). If primary element does not pull out with ease, move side-to-side.

  4. When air cleaner element must be serviced in field, tap it on the palm of your hand. Do not use compressed air or filter damage occurs.

  5. Inspect guide ring (E) for damage.

  6. Replace elements if core material or seals (both ends) are damaged, or if indicator remains illuminated.

  7. Install elements and reinstall latch cover.

  8. Lower hood.

GS25068,0005AEE-19-20181010