Change Transmission/Hydraulic Filter

MAINTENANCE INTERVAL

 

INITIAL — 100 Hours

 

REGULAR — Every 600 Hours

RXA0146168
RXA0146168-UN-03NOV14

LV9610
LV9610-UN-10AUG04

A - Cover

B - Filter Element

C - Housing


IMPORTANT: Capture oil from reservoir and filter using a drain pan. Dispose of waste oil properly.

  1. Park machine on level ground, shut off engine, and remove key.

  2. Remove cover (A) and filter.

  3. Separate filter element (B) from cover. Discard filter element.

  4. Clean cover, threads on the filter housing, and seal inside cover.

  5. Assemble new filter element and cover. Filter should snap into cover.

  6. Install cover and filter assembly.

  7. Run engine several seconds and check transmission/hydraulic system oil level. (See Check Transmission/Hydraulic System Oil Level in this section.)

  8. Add transmission/hydraulic oil as required. (See Fuel, Lubricants, and Coolants section for correct oil.)

GS25068,0005B0B-19-20181010