Keep Roll-Over Protective Structure (ROPS) Installed Properly

CAUTION: Make certain all parts are installed correctly if roll-over protective structure (ROPS) is loosened or removed for any reason. Replace and tighten mounting cap screws to specification.

If ROPS is subjected to structural damage, as in an overturn incident, the protection a ROPS offers is impaired. Protection is also impaired if ROPS is in any way altered via welding, bending, drilling, or cutting. Replace damaged ROPS, do not reuse. Any alteration to the ROPS requires approval by the manufacturer.

RXA0147448
RXA0147448-UN-23FEB15

CPA0004258
CPA0004258-UN-09AUG17

A - Roll-Over Protective Structure (ROPS)

B - Mounting Cap Screw (8 used)


When installation of equipment on a machine necessitates loosening or removing roll-over protective structure (ROPS) (A), replace and tighten mounting cap screws (B) to specification.

ItemMeasurementSpecification
ROPS Mounting Cap ScrewsTorque365 N·m (284 lb·ft)