Keep Roll-Over Protective Structure (ROPS) Installed Properly
CAUTION: Make certain all parts are installed correctly if roll-over
protective structure (ROPS) is loosened or removed for any reason.
Replace and tighten mounting cap screws to specification. If ROPS is subjected to structural damage, as in an overturn incident,
the protection a ROPS offers is impaired. Protection is also impaired
if ROPS is in any way altered via welding, bending, drilling, or cutting.
Replace damaged ROPS, do not reuse. Any alteration to the ROPS requires
approval by the manufacturer.

RXA0147448-UN-23FEB15

CPA0004258-UN-09AUG17
A - Roll-Over Protective Structure (ROPS)
B - Mounting Cap Screw (8 used)
When installation of equipment on a machine necessitates loosening
or removing roll-over protective structure (ROPS) (A), replace and
tighten mounting cap screws (B) to specification.
| Item | Measurement | Specification |
|
ROPS Mounting Cap Screws | Torque | 365 N·m (284 lb·ft) |
|
|
GS25068,0005B2E-19-20181010
|
|