Set SCV Detents
Setting SCV Lever Detents

LV22089-UN-12JUN14

LV22090-UN-12JUN14

LV22102-UN-12JUN14
A - SCV Knob
B - Read Operator Manual
C - Continuous Detent (Motor)
D - No Detent (Loader)
E - Automatic Detent (Cylinder)
IMPORTANT: To avoid overheating hydraulic oil and damage to
machine, use SCV I when long duration “continuous” (motor) operation
is required. Section I of deluxe SCV has a flow control valve. When
properly adjusted, valve provides flow to operate an implement at
required speed while maintaining oil temperature within normal operating
range.
Section 1 of the deluxe SCV has selectable detents, used to
change multi-function lever operations to meet operating requirements
of different implements. Detent settings affect only extend and retract
lever positions, not “float.”
NOTE: Read operator manual (B) is for reference only and is
not a selectable setting.
|
SCV Knob Position
|
SCV Lever Detent
|
|
Continuous Detent (Motor) (C) for motor operation
|
Holds lever in operating position until manually returned to
neutral.
|
|
No Detent (Loader) (D) for loader operation
|
Lever returns to neutral when released.
|
|
Automatic Detent (Cylinder) (E) for cylinder operation
|
Lever automatically returns to neutral when a cylinder reaches
the end of stroke.
|
|
|
OURX985,00031F0-19-20190607
|
|