Operate Power Beyond with Rear SCV

RXA0149424
RXA0149424-UN-22JUL15

LV22103
LV22103-UN-17JUN14

A - SCV I Extend Coupler

B - SCV I Detent

C - Continuous Detent Position


IMPORTANT: Power beyond connections must be used when operating any external hydraulic orbital motor with this machine. Failure to comply with power beyond connections overheats and possibly damages the hydraulic system.

  1. NOTE: Oil can be supplied to power beyond equipment using SCV 1 on the deluxe SCV (in continuous mode) or by using a power beyond kit with the standard dual rear SCV.

    Shut off engine.

  2. Connect power beyond hose to SCV I extend coupler (A).

  3. Set rear SCV I detent (B) to continuous (C).

  4. Start engine.

  5. Move SCV I lever into extend.

  6. Oil is now supplied to power beyond device.

  7. To stop, de-activate power beyond device, then return SCV I lever to neutral.

  8. Shut off engine and disconnect hoses.