Removing Batteries

causym CAUTION: Battery gas can explode. Keep sparks and flames away from batteries. Use a flashlight to check battery electrolyte level. Never check battery charge by placing a metal object across the posts. Use a voltmeter or hydrometer. Always remove grounded (-) battery clamp first and replace it last.

Your machine may be equipped with one or two 12-volt hybrid batteries with negative ground. Use only batteries meeting following specifications:

IMPORTANT: Check for worn or frayed wires and loose or corroded connections.

1. Disconnect negative (-) battery cables first, then positive (+) cables.

2. Remove nuts and hold down brackets.

3. Lift batteries out of compartment.

T7945AH
TS204