Stopping the Engine-Normal Shutdown With Powershift Transmission
IMPORTANT:
Before stopping engine that has been operating at working load, idle at 1/3 speed for 1-2 minutes to cool the engine. If engine stalls while operating under load, restart immediately and idle at 1/3 speed for 1-2 minutes before stopping to allow coolant to continue circulating through engine.
IMPORTANT:
Turbocharger may be damaged if engine is not properly shut down.
1.
Park machine on a level surface.
2.
Lower all equipment to ground.
3.
Move FNR/range lever (A) to NEUTRAL.
CAUTION:
Prevent possible injury from unexpected machine movement. NEVER rely on FNR/range lever alone to keep machine from moving. Always engage park brake to hold machine.
4.
Push left half of park brake switch (C) to engage park brake.
5.
Move engine speed control lever (E) to 1/3 speed and run engine with no load for 1-2 minutes.
6.
Move engine speed control lever to SLOW IDLE.
7.
Turn key switch (F) to OFF to stop engine. Remove key from key switch.
8.
Release hydraulic pressure by moving control levers until equipment does not move.
|