Fill and Charge Pressurized Water System-If Equipped
CAUTION:
Release pressure by discharging fluid at hose and before removing fill plug. Injury may result from plug or cap under force.
1.
Move shut-off valve lever (A) to turn water on.
2.
Squeeze nozzle lever (D) to spray water.
3.
Slowly remove plug (E).
IMPORTANT:
Avoid machine damage. Add 25 kg (55 lb) calcium chloride to water tank before air temperature drops below 0°C (32°F).
4.
Fill tank with water.
Specification
|
Water Tank
-Capacity
|
60.6 L (16 gal) Approximate
|
CAUTION:
Plug has a vent cross hole for release of air pressure. Do not use a substitute plug.
5.
Install plug.
6.
To pressurize system, connect air hose to fitting (B) and add air. Watch gauge (C) for correct air pressure.
Specification
|
Water Tank
-Pressure
|
410 kPa (3.8 bar) (55 psi)
|
|