Using Booster Batteries-24-Volt System
Before boost starting, machine must be properly shut down and secured to prevent unexpected machine movement when engine starts.
CAUTION:
An explosive gas is produced while batteries are in use or being charged. Keep flames or sparks away from battery area. Make sure the batteries are charged in a well ventilated area.
IMPORTANT:
The machine electrical system is a 24-volt negative (-) ground. Connect 2 12-volt booster batteries together in series as shown for 24-volts.
1.
Connect one end of positive cable to positive terminal of machine batteries and other end to positive terminal of booster batteries.
2.
Connect one end of negative cable to negative terminal of booster batteries. Connect other end of negative cable to machine frame as far away from machine batteries as possible.
3.
Start engine.
4.
Immediately after starting engine, disconnect end of negative cable from machine frame. Then disconnect other end of negative cable from negative terminal of booster batteries.
5.
Disconnect positive cable from booster batteries and machine batteries.
|