Adjusting Auxiliary Hydraulic Linkage-Hand-Foot Machines
The auxiliary hydraulic linkage goes down through the right control lever to the control valve.
1.
Park machine.
2.
Lock boom in raised position.
3.
Remove center cover plate.
4.
Rotate handle all the way up and all the way down. Ensure that the valve locks into detent.
5.
Confirm that when handle is returned to the neutral position, the locking mechanism (1) will engage without movement of the handle.
6.
If necessary, adjust position of cable forward or backward using nuts (2) to properly position handle.
7.
Install center cover plate, and lower boom to ground.
1-Locking Mechanism
2-Nuts
|