Check Hydraulic Tank Oil Level
IMPORTANT:
To ensure an accurate reading, park machine on smooth level ground and check level only when hydraulic oil is cold and boom is down with boom and bucket cylinders fully retracted.
When adding oil to the hydraulic tank, be careful not to get dirt into tank or oil.
Do not overfill hydraulic oil tank. An overfilled hydraulic oil tank will not allow for oil expansion, which may result in oil leakage past hydraulic tank breather or fill cap.
1.
Park machine.
2.
Check oil level at sight glass (1).
3.
Add oil if necessary: See Maintenance-Machine. (Section 3-1.)
4.
Open rear service door and engine cover, and remove right side panel.
-
Remove filler cap (2). Fill hydraulic oil tank.
-
Install filler cap.
5.
Close engine cover and rear service door.
6.
Install side panel.
|