Monthly Storage Procedure

causym CAUTION: Prevent possible injury or death from asphyxiation. Engine exhaust fumes can cause sickness or death. Start engine ONLY in a well-ventilated area.

1. Drain water and sediment from fuel tank when air temperature is above freezing.

2. Remove LPS 3 ® Rust Inhibitor from cylinder rods with a cleaning solvent.

T6191AA

LPS 3 Rust Inhibitor is manufactured by Holt Lloyd Corporation.

VD76477,00016A3 -19-08JAN08-1/3


IMPORTANT: Prevent possible engine damage. During cold temperatures, check fluidity of engine oil on dipstick. If the oil appears waxy and/or jelly-like rather than liquid, DO NOT attempt to start engine. Use external heat source to warm the crankcase until oil appears fluid.

3. Check all fluid levels. If low, check for leaks and add oil as required.

4. Check belts.

5. Check condition of all hoses and connections.

6. Check battery electrolyte level. Charge and install battery.

7. For machines with tires , check condition of tires and tire pressure.

For machines with tracks , check condition of tracks and track sag.

On crawler machines with non sealed-and-lubricated track chains, apply oil to the pin-to-bushing joints. Run machine back and forth several times.

8. Park machine on a hard surface to prevent tracks from freezing to ground.

9. Fill fuel tank.

10. Pre-lubricate turbocharger bearings, if equipped:

a. Disconnect fuel shutoff fuse.

b. Crank engine for 10 seconds.

c. Connect fuel shutoff fuse.

11. Inspect engine compartment, and remove any foreign material that may have accumulated. Start engine and run until it reaches operating temperature. Run at 1/2 speed for five minutes. Do not run at fast or slow idle.

T6181AU

VD76477,00016A3 -19-08JAN08-2/3


  • If engine fails to start or runs poorly after starting, change fuel filter(s). Bleed fuel system.
12. Operate all controls, levers, seat adjustments, etc.

causym CAUTION: Prevent possible injury from unexpected machine movement. Clear the area of all persons before running machine through the operation procedure.

13. Make sure the area is clear to allow for movement. Cycle all hydraulic functions several times. Check condition of all hoses and connections.

14. Park the machine with cylinder rods retracted, if possible. Turn key switch to OFF.

15. Apply LPS 3 Rust Inhibitor to exposed cylinder rod areas.

VD76477,00016A3 -19-08JAN08-3/3