Starting the Engine
CAUTION: Avoid injury! Engine exhaust fumes contain carbon monoxide
and can cause serious illness or death. • Move the
machine to an outside area before running the engine.
• Do not run an engine in an enclosed area without adequate
ventilation.
• Connect a pipe extension to the engine exhaust pipe to
direct the exhaust fumes out of the area.
• Allow fresh outside air into the work area to clear out
the exhaust fumes.
NOTE: Diesel Models: Make sure fuel shutoff valve is open.
-
Park vehicle safely. (See Parking Safely in the Safety section.)
-
Push hydraulic PTO lever to the off position.
-
Move the gearshift lever to the neutral position.
-

TCAL45014-UN-14MAY13
Turn key switch to the run position (A).
-
Check indicator lights:
-
Battery discharge indicator light must be on.
-
Park brake indicator light must be on.
-
Engine oil pressure indicator light must be on.
-
Diesel Models: Glow plug indicator
light must be on. After approximately three seconds, the indicator
light goes off. Engine is now ready to start.
-
IMPORTANT: Avoid damage! Starter can be damaged if operated
for more than 20 seconds at a time. Wait at least two minutes before
trying again if engine does not start.
Turn key switch to the start position (B).
-
NOTE: Engine is calibrated at the factory to slow idle when
started as follows: • Diesel engine - 1250 rpm ±
50
• Gas engine - 1000 rpm ± 10
When engine starts, release key switch to the run position.
-
Battery discharge indicator light must go out.
-
Engine oil pressure indicator light must go out.
-
Unlock park brake.
-
Park brake indicator light must go out.
|
DK75838,00007B7-19-20150629
|
|