Service Intervals After Converting to BioDiesel Fuel
IMPORTANT: Avoid damage! Only use BioDiesel fuel that complies
with EN14214 (European Standards) or ASTM D-7467 (USA Standards) in
B6 through B20 blends. BioDiesel fuel must be used within
three months of the date of production by the fuel supplier.
NOTE: The use of John Deere BioDiesel Fuel Conditioner is recommended
whenever a BioDiesel blended fuel is used.
Use the following service procedures at the intervals listed
for machines converted to use BioDiesel B6-B20 fuel blends:
Daily
-
Check and drain water separator as required.
-
Check engine oil. If oil level rises, change engine oil immediately.
Engine Oil and Filter Change Interval
-
Change at 50% of Service Interval listed in Operator Manuals
for regular diesel fuel usage.
Fuel Filter Change Interval
-
Change at 50% of Service Interval listed in Operator Manuals
for regular diesel fuel usage.
Every 1000 Hours
-
Clean, inspect, and adjust fuel injectors.
|
DK75838,00007D2-19-20150629
|
|