Service Intervals After Converting to BioDiesel Fuel

IMPORTANT: Avoid damage! Only use BioDiesel fuel that complies with EN14214 (European Standards) or ASTM D-7467 (USA Standards) in B6 through B20 blends.

BioDiesel fuel must be used within three months of the date of production by the fuel supplier.

NOTE: The use of John Deere BioDiesel Fuel Conditioner is recommended whenever a BioDiesel blended fuel is used.

Use the following service procedures at the intervals listed for machines converted to use BioDiesel B6-B20 fuel blends:


Daily

  • Check and drain water separator as required.
  • Check engine oil. If oil level rises, change engine oil immediately.

Engine Oil and Filter Change Interval

  • Change at 50% of Service Interval listed in Operator Manuals for regular diesel fuel usage.

Fuel Filter Change Interval

  • Change at 50% of Service Interval listed in Operator Manuals for regular diesel fuel usage.

Every 1000 Hours

  • Clean, inspect, and adjust fuel injectors.

DK75838,00007D2-19-20150629