Cleaning Oil Cooler
CAUTION: Avoid injury! Compressed air can cause debris to fly
a long distance. • Clear work area of bystanders.
• Wear eye protection when using compressed air for cleaning
purposes.
• Reduce compressed air pressure to 210 kPa (2.10 bar)
(30 psi).
IMPORTANT: Avoid damage! Cooling fins must be clean to prevent
engine from overheating and to allow adequate air intake.
NOTE: Perform this service procedure on vehicles equipped with
auxiliary hydraulic kit.
-
Raise attachment to service position. (See Using the Lift Cylinder
Safety Support in the Safety section.)
-
Park vehicle safely. (See Parking Safely in the Safety section.)
-

TCT011008-UN-16APR14
Lift air intake screen (A) from position in front of the
engine radiator.
-
Remove dirt and debris from the auxiliary hydraulics an oil
cooling coils (B) using compressed air or water. Check coils for damage.
-
Install air intake screen.
-
Lower attachment.
|
OUMX068,0000747-19-20150630
|
|