Service Intervals After Converting to BioDiesel Fuel
IMPORTANT: Only use biodiesel fuel that complies with EN14214
(European Standards) or ASTM D-7467 (USA Standards) in B6 through
B20 blends. Biodiesel fuel must be used within three months
of the date of production by the fuel supplier.
NOTE: The use of John Deere Biodiesel Fuel Conditioner is recommended
whenever a biodiesel blended fuel is used.
Use the service procedures below at the intervals listed for
machines converted to use biodiesel B6-B20 fuel blends:
Daily
-
Check and drain water separator as required.
-
Check engine oil. If oil level rises, change engine oil immediately.
Engine Oil and Filter Change Interval
-
Change at 50% of Service Interval listed in Operator Manuals
for regular diesel fuel usage.
Fuel Filter Change Interval
-
Change at 50% of Service Interval listed in Operator Manuals
for regular diesel fuel usage.
Every 1000 Hours
-
Clean, inspect and adjust fuel injectors.
|
|
DK75838,00006E2-19-20130322
|
|