Parked Regeneration
IMPORTANT: Avoid damage! If operator disregards indicators and
continues to operate machine without allowing an automatic cleaning,
engine performance is reduced and machine function limited. A parked
regeneration procedure must be performed.
TCT012275-UN-03FEB15
The following occurs when exhaust filter becomes restricted:
-
TechControl alert with DTC 3719.16 becomes active.
-
Engine power is reduced and machine function limited.
Currently, a parked exhaust filter cleaning is required.
Before completing a parked exhaust filter cleaning, the following
criteria must be met:
-
Engine running at low idle.
-
Coolant temperature must be above
60° C (140° F).
-
Park brake must be engaged.
-
PTO must be turned off.
-
IMPORTANT: Avoid damage! No other machine functions are able
to be used while regeneration is taking place with the machine parked.
Excluded are functions that are required for an emergency shutdown
of the machine. Do not start regeneration if the fuel
gauge has been showing a low fuel level for a long time.
Only stop engine if necessary due to heat build up in the engine
compartment.
NOTE: When the previous criteria are met, the parked regeneration
icon (A) blinks indicating parked regeneration can be initiated.
TCT012270-UN-28JAN15
Press and hold button 1 under the parked regeneration icon
(A) on TechControl DPF status screen for 5 seconds.
NOTE: If cancellation of parked regeneration is necessary, your
best option is to depress button 4 under icon (B) on the TechControl
DPF status screen.
-
TCT012271-UN-03FEB15
During parked regeneration process, the high exhaust temperature
icon with progress bar appears on the TechControl DPF status screen
as shown.
-
The engine speed elevates to 2200 rpm.
-
After completion of parked regeneration process, the system
defaults to auto regeneration mode and the machine operates as normal.
NOTE: If not returning machine to operation, allow engine time
to return to normal operating temperature before stopping engine.
IMPORTANT: Avoid damage! If operator disregards indicators and
continues to operate machine without allowing a parked regeneration,
engine performance is reduced and machine function limited. A recovery
regeneration procedure by a John Deere dealer is required.
|
TC00531,00000BA-19-20150205
|
|